Airflow experts: small server build log

post #1 of 5
Thread Starter 
Hey,

I am working on building for some time now a case for a really tiny server. What I expect him to do:
- file server: lots of space, data security
- all around connectivity
- low consumption, low noise
- no wires (except plug) and small.

Tech solutions:

- 2x500GB HDDs (brand unknown for now) in RAID 1
- connectivity Wi-FI (n draft), Bluetooth, eventually remote control TT Mozart style
- sempron 2800+ CPU passive, AMD 690G chipset, fans piloted by a electronic card I made in function of temperature (max supported =2 fans)
- home made wooden box with a metal frame

It's not exactly in chronological order as I've began it 2 months ago working now and then, but it's surely the logical order in which should have been done.

The main problem is heat - I have chose everything to enter a 150-170W power envelope and a minuscule volume.

The shopping chart:

Bought a cheapo 480W PSU (10$) that should provide 200w without overheating, an ASUS M2N-VM 690G, and reused 2GB of Ballistix DDR667, a 8GB old HDD and a 2800 sempron I had laying around.

The PSU:

Any ATX PSU is far to big for what I intended so I simply took out the PSU PCB out of the iron case; you'd be surprised how much space is wasted.

After this I bend the radiators to occupy a smaller volume - this doesn't change anything in their cooling abilities.

I removed the 120mm fan as there wasn't any room for it so the PSU became passive and as a result dead silent.

After this diet, the PSU is just the size of two cigarette packs one on top of the other - and it works (tested and retested every step of the way)

Sometime later, after mounting everything in the small case I built (details below) I realized the wires for the ATX 24 pin connector were too long and filling literally every cubic inch of air available in the case. They lost some weight also, some 8cm from the 15cm in total(4" from say 8" for the imperial units) in total to be just as long as they have to barely reach the ATX plug in the mobo.

THE CASE

The principle of the case is in the picture below. It has to be just a bit taller than a PCI card, and sufficiently wide as to receive a 25x25cm µATX board.


Since the server needed to be really small, silent and more than anything cost effective it seemed obvious from the get-go that I had to build it myself. I had no experience in welding, but fortunately I have friends, beer and jokes in my schedule, so a total of 3 guys were enough to cut some iron plates that were to form the skeleton, weld them together to have the frame and cut the wood plates that were to silence the beast inside.

And a lesson to others reading and living in a flat: always a keep good relationship with the neighbors, 'cause they can get really pissed when hearing an electric drill at 10 p.m. If you have invited them to you barbecue the other day, they'd be easier to accept these phonic aggressions that are inevitable when building something.

I'm a highly mathematical person, I like to calculate everything in the smallest of details, the angles, distances so that there is a perfect fit. It just so happens that from the start of the project I supposed the PSU rad and the CPU rad would be face-to-face and touching.
Obviously, the hours of thorough calculations were brought to nothing when we realized that we forgot to take into consideration the effective thickness of the wooden plates. They're only 4mm thick, but enough to make us miss the overall inside height of the case by 5mm (more or less). This in turns meant some more modifying of the PSU's radiators...

Cooling as it was originally thought

The idea was that a 80mm fan I had laying around to pull hot air from the area that contains the radiators of the PSU/CPU/NB . It's sorta like a tunnel where the fresh air enters thru somewhere (not exactly defined in a first approach), is being routed in one end of the box, traverses the radiators that are packed together and is being pulled outside by the 80mm silent fan, much like this picture below:

I figured I'll see where to make the intake hole for the air to get in as the case is in wood afterall and holes can be made easily. The idea was the hole to be where the eventual hotspot is.


The assembly

Well, having worked for two months I was burning to see all the stuff in the case and install a Win2000 SP3 copy I have since a while ago when my main rig wasn't powerful enough to handle the "enormous memory requirements of windows XP".

BTW, Vista a memory hog? When XP appeared, the 128MB of ram became highly insufficient. 256 minimum for XP. XP SP2 upped to 512 minimum with 1GB to be smooth. In total there was a 4x multiply in ram needs over XP's lifetime. Vista say it needs 4GB to be smooth, so why all the hustle? And what did XP bring, some more eye candy vs Win2000. Same old story...

Now in the assembly, as stated earlier, I quickly found out the ATX cables have to be put on a diet. I welded for over 3 hours, since I'm not very good. I didn't want to make any mistake, as it would fry the mobo 'cause that would have sucked.

Windows install

All smooth, nothing to see Except the fact it was installed in open-air (aka no case) because I needed a PATA cable connected for the DVD-ROM; the server won't have any optical unit.
A small issue that wasn't so obvious at the beginning was the lack of drivers for the 690G chipset in Windows 2000. Some XP drivers worked, others didn't...

Burning tests

Now the fun part: cooling design. Remember I have only one fan that is pulling air. From where? Dunno, probably from the hinges of the wooden case. The only purpose of this test was to identify the major heat sources. Anyway, after 20mn of 100% CPU it went at 47°C and still rising. Shutdown and back to the drawing board.

There seemed obvious 2 hotspots:


The CPU was the hottest thing around, the PSU rads didn't seem to hot. In the lower floor where the HDDs are isolated (in this test it is actually only one HDD) it heated up a bit too.

Advice time

Now there are ways to tackle this issue and I thought of two scenarios pictured below:
1. Put a 80 mm intake fan in the right, output in the left and venting holes to ventilate the hdd are

2. Put a 80 mm output fan in the right, seal on the left and in the HDD bay area make a hole below the HDDs for the air intake, and make a hole in the left, so that the warm air rises and further cools the array of radiators; here I suppose the HDDs will not overheat since I suppose I'm getting Caviar GPs:



What do you think of the build, the story, the server, and more importantly, how do you see the cooling system to be as efficient as possible?

Thanks for reading, if you got this far you deserve a beer or at least an OCN's rep.

Drago
Centurion
(14 items)
 
  
CPUMotherboardGraphicsRAM
Phenom II 940 @3.3GHz 1.25V Gigabyte 790X-DS4 XFX 5850 8GB OCZ DDR2-800 
Hard DriveCoolingOSMonitor
Corsair Force 3 TRUE Win 7 Pro x64 ACER 23" TN  
PowerCase
400W Silverstone Strider Antec P182 
  hide details  
Reply
Centurion
(14 items)
 
  
CPUMotherboardGraphicsRAM
Phenom II 940 @3.3GHz 1.25V Gigabyte 790X-DS4 XFX 5850 8GB OCZ DDR2-800 
Hard DriveCoolingOSMonitor
Corsair Force 3 TRUE Win 7 Pro x64 ACER 23" TN  
PowerCase
400W Silverstone Strider Antec P182 
  hide details  
Reply
post #2 of 5
If there's space under the hard drives, just put a small fan on the side of the case and another one on the opposite side. It may not generate a huge airflow, but it should help a lot.



This one looks good. But if you do what I said above, you'll probably have better temps in both areas.
Dark Helmet
(13 items)
 
  
CPUMotherboardGraphicsRAM
Q6600 G0 @ 3.4ghz, 1.39v DFI LP UT P35-T2R XFX 6970 4gb G.Skill PC8000, 2gb G.Skill PC8500 
Hard DriveOSMonitorKeyboard
OCZ Vertex 2 60gb, WD Black 1tb, Samsung F1 1tb Windows 7 x64 Samsung 206bw Razer Tarantula 
PowerCaseMouse
Seasonic X650 Antec P182 Razer DeathAdder 
  hide details  
Reply
Dark Helmet
(13 items)
 
  
CPUMotherboardGraphicsRAM
Q6600 G0 @ 3.4ghz, 1.39v DFI LP UT P35-T2R XFX 6970 4gb G.Skill PC8000, 2gb G.Skill PC8500 
Hard DriveOSMonitorKeyboard
OCZ Vertex 2 60gb, WD Black 1tb, Samsung F1 1tb Windows 7 x64 Samsung 206bw Razer Tarantula 
PowerCaseMouse
Seasonic X650 Antec P182 Razer DeathAdder 
  hide details  
Reply
post #3 of 5
i wrote a faq on case fans some time back. it may give you some hints. the link is below in my signature.
    
CPUMotherboardGraphicsRAM
E8400 @ 4.1 GHz ASUS Maximus Formula Undecided Corsair Dominator 4GB @ 910 
Hard DriveOSPowerCase
Barracuda 250GBx2 Raid 0 XP Hiper 880W Thermaltake ArmorPlus 
  hide details  
Reply
    
CPUMotherboardGraphicsRAM
E8400 @ 4.1 GHz ASUS Maximus Formula Undecided Corsair Dominator 4GB @ 910 
Hard DriveOSPowerCase
Barracuda 250GBx2 Raid 0 XP Hiper 880W Thermaltake ArmorPlus 
  hide details  
Reply
post #4 of 5
Wow!

What a great Post; so organized and with great visual aids.

As tehpwn stated the crossflow is optimal.

In regards to "silence": If you can, use 120mm fans as the cfm/dba ratio on larger fans is better than 80mm.

If you must use 80's, then perhaps the Silverstone FN181's would be good. They mount in the 80mm space, but have more of a 90mm diameter as the fans chassis design is round and not square.
Flux
(13 items)
 
  
CPUMotherboardGraphicsRAM
i7 2600K GA-P67A-UD7 GTX 580 2 x 2GB Corsair 
Hard DriveOptical DriveOSMonitor
C300 (OS), Velociraptor (storage) Lite-On W7 64-bit Pro Samsung 275T 
KeyboardPowerCaseMouse
Black Widow Ult. Silverstone DA750 Lian Li T60 R.A.T. 7 
Mouse Pad
Q-Pad 
  hide details  
Reply
Flux
(13 items)
 
  
CPUMotherboardGraphicsRAM
i7 2600K GA-P67A-UD7 GTX 580 2 x 2GB Corsair 
Hard DriveOptical DriveOSMonitor
C300 (OS), Velociraptor (storage) Lite-On W7 64-bit Pro Samsung 275T 
KeyboardPowerCaseMouse
Black Widow Ult. Silverstone DA750 Lian Li T60 R.A.T. 7 
Mouse Pad
Q-Pad 
  hide details  
Reply
post #5 of 5
Thread Starter 
Quote:
Originally Posted by ldk View Post
i wrote a faq on case fans some time back. it may give you some hints. the link is below in my signature.
Thanks, it was actually a very good read. What do you think of the solutions I proposed 1 and 2?

Quote:
Originally Posted by tehpwnerofn00bs View Post
If there's space under the hard drives, just put a small fan on the side of the case and another one on the opposite side. It may not generate a huge airflow, but it should help a lot.



This one looks good. But if you do what I said above, you'll probably have better temps in both areas.
Unfortunately I think I have just about 3-4mm under the HDDs. I can still buy laptop HDDs (2.5" kind), but they are too expensive. I'll give it a go with one of the single-platter 7200.10 I have, as they are slimmer by 3mm than a regular 5.25 incher and I may just about get the clearance I need, but it's too close to call.

Quote:
Originally Posted by Syrillian View Post
Wow!

What a great Post; so organized and with great visual aids.

As tehpwn stated the crossflow is optimal.

In regards to "silence": If you can, use 120mm fans as the cfm/dba ratio on larger fans is better than 80mm.

If you must use 80's, then perhaps the Silverstone FN181's would be good. They mount in the 80mm space, but have more of a 90mm diameter as the fans chassis design is round and not square.
Thanks for reading, I meant it to be as pleasant as possible since it's very long. Without pictures it would have been too tough to explain what I mean.

Unfortunately I have no place for a 120mm, at least not for an unmodified one . Right now I was thinking if only I could put the edges of the fan on a diet... if it were only 120mm it may fit. I guess I'll just have to cut all the outer portion of the fan and leave it only with the inner part with the blades and engine... and after that to find a way to fix it on the case.
------------------------------------------------------------------
So for the first config with airflow from felt to right, wouldn't it be kinda hard for the HDDs to cool?

As for the second configuration, with a fan on the left that would exhaust air outside the case, is it too far fetch? The fan would create a negative pressure inside the top part of the case which would work in the natural flow of air. I imagine the air-friction from the bottom of the case and thru the myriad of radiators would make the fan work hard, but is it doable?

Cheers
Centurion
(14 items)
 
  
CPUMotherboardGraphicsRAM
Phenom II 940 @3.3GHz 1.25V Gigabyte 790X-DS4 XFX 5850 8GB OCZ DDR2-800 
Hard DriveCoolingOSMonitor
Corsair Force 3 TRUE Win 7 Pro x64 ACER 23" TN  
PowerCase
400W Silverstone Strider Antec P182 
  hide details  
Reply
Centurion
(14 items)
 
  
CPUMotherboardGraphicsRAM
Phenom II 940 @3.3GHz 1.25V Gigabyte 790X-DS4 XFX 5850 8GB OCZ DDR2-800 
Hard DriveCoolingOSMonitor
Corsair Force 3 TRUE Win 7 Pro x64 ACER 23" TN  
PowerCase
400W Silverstone Strider Antec P182 
  hide details  
Reply
New Posts  All Forums:Forum Nav:
  Return Home
  Back to Forum: Air Cooling
Overclock.net › Forums › Cooling › Air Cooling › Airflow experts: small server build log