Quote:
Originally Posted by Starbuck5000 View Post
If I want to use the LSI drives do I need to be using the LSI firmware?
What strip size and other settings should I use for the Raid 5 array, caching stripe size etc...?
In my experience using Windows XP & XP x64 you can't use the LSI drivers on the Dell cards even if they are flashed with the LSI firmware. However, you can use the LSI MSM software regardless of Dell or LSI firmware.

I'd recommend a large stripe size like 512k.
post #3502 of 7179
Quote:
Originally Posted by Starbuck5000 View Post
What strip size and other settings should I use for the Raid 5 array, caching stripe size etc...?
What is the array for? And what kind of files does it contain?

RAID5 for OS = bad idea, so I hope it is for file storage.

Larger files (media etc), go large stripe size (256k+). Smaller files (documents etc) go smaller (64-128k).

Caching - 'write back' if you have a battery or just want max speed with a slight risk of failure if you have no battery. 'Write back' if you have no battery and want max security.
post #3503 of 7179
Quote:
Originally Posted by Stereodude View Post
In my experience using Windows XP & XP x64 you can't use the LSI drivers on the Dell cards even if they are flashed with the LSI firmware. However, you can use the LSI MSM software regardless of Dell or LSI firmware.

I'd recommend a large stripe size like 512k.
Cheers Stereo

Quote:
Originally Posted by the_beast View Post
What is the array for? And what kind of files does it contain?

RAID5 for OS = bad idea, so I hope it is for file storage.

Larger files (media etc), go large stripe size (256k+). Smaller files (documents etc) go smaller (64-128k).

Caching - 'write back' if you have a battery or just want max speed with a slight risk of failure if you have no battery. 'Write back' if you have no battery and want max security.
Why is Raid 5 for OS bad, imo Raid 5 sounds great for your os increased speed from striping plus the added redundancy from parity meaning if a drive fails you don't have to suffer down time?

I do have a BBU for this
Edited by Starbuck5000 - 10/31/09 at 9:56am
Roger Rabbit
(10 items)
 
  
CPUMotherboardGraphicsRAM
Core i7 3930k  Asus P9X79 Pro Evga 1080 FTW DT 16GB Corsair Vengeance LPX at 2100MHZ 
MonitorMonitorKeyboardCase
Acer Predator XB271HU Dell U2715H Ducky /w Cherry Black's Phanteks Enthoo Evolv ATX TG 
MouseAudio
Logitech G502 Audnist MUX-1 > HD 600's 
  hide details  
Reply
Roger Rabbit
(10 items)
 
  
CPUMotherboardGraphicsRAM
Core i7 3930k  Asus P9X79 Pro Evga 1080 FTW DT 16GB Corsair Vengeance LPX at 2100MHZ 
MonitorMonitorKeyboardCase
Acer Predator XB271HU Dell U2715H Ducky /w Cherry Black's Phanteks Enthoo Evolv ATX TG 
MouseAudio
Logitech G502 Audnist MUX-1 > HD 600's 
  hide details  
Reply
post #3504 of 7179
Quote:
Originally Posted by Starbuck5000 View Post
Why is Raid 5 for OS bad, imo Raid 5 sounds great for your os increased speed from striping plus the added redundancy from parity meaning if a drive fails you don't have to suffer down time?
Because every time you make a small write to the drives (and OSes do this a lot), you have to read data from all the drives in order to recalculate the parity & then write the new data & the new parity bit. This kills any striping benefit, although the cache helps a little to offset the effect.

For OS use I would run RAID10 or just image your drives frequently instead of using redundancy and run RAID0.
post #3505 of 7179
Quote:
Originally Posted by the_beast View Post
Because every time you make a small write to the drives (and OSes do this a lot), you have to read data from all the drives in order to recalculate the parity & then write the new data & the new parity bit. This kills any striping benefit, although the cache helps a little to offset the effect.

For OS use I would run RAID10 or just image your drives frequently instead of using redundancy and run RAID0.
Didn't know that, I'll give it some thought
Roger Rabbit
(10 items)
 
  
CPUMotherboardGraphicsRAM
Core i7 3930k  Asus P9X79 Pro Evga 1080 FTW DT 16GB Corsair Vengeance LPX at 2100MHZ 
MonitorMonitorKeyboardCase
Acer Predator XB271HU Dell U2715H Ducky /w Cherry Black's Phanteks Enthoo Evolv ATX TG 
MouseAudio
Logitech G502 Audnist MUX-1 > HD 600's 
  hide details  
Reply
Roger Rabbit
(10 items)
 
  
CPUMotherboardGraphicsRAM
Core i7 3930k  Asus P9X79 Pro Evga 1080 FTW DT 16GB Corsair Vengeance LPX at 2100MHZ 
MonitorMonitorKeyboardCase
Acer Predator XB271HU Dell U2715H Ducky /w Cherry Black's Phanteks Enthoo Evolv ATX TG 
MouseAudio
Logitech G502 Audnist MUX-1 > HD 600's 
  hide details  
Reply
post #3506 of 7179
Quote:
Originally Posted by Starbuck5000 View Post
If I want to use the LSI drives do I need to be using the LSI firmware?
Quote:
Originally Posted by Stereodude View Post
In my experience using Windows XP & XP x64 you can't use the LSI drivers on the Dell cards even if they are flashed with the LSI firmware. However, you can use the LSI MSM software regardless of Dell or LSI firmware.
I don't know if you can use an LSI driver with a Dell firmware, but I'm actually using (perc 5/i) an LSI driver with an LSI firmware without problems on Vista x64.
A friend of mine is using the Dell driver with the LSI firmware on XP (the opposite).

The main problem is the Hardware ID. Also if you change the firmware, the HW ID is the same (the DELL; PCI\\VEN_1028&DEV_0015 for the perc 5/i).
With my Vista x64 I can install the LSI drivers without problems selecting manually the driver (it complains that the driver compatibility isn't verified, but it's ok).
With Windows XP I think that you have to modify the drivers. Probably the megasas.cat file and also the oemsetup.inf adding the Dell HW IDs to the oemsetup.inf file, but I can't verify that.

If you are using Windows 7 I don't think that you have any problem.
I'm using the last LSI driver (3.9.0.64) from the LSI MegaRAID SAS 8704EM2 support page. The 8704EM2 card is completely different (the perc is an 8408E controller) but the driver available from here is newer and compatible also with the perc 5.
My System
(13 items)
 
  
CPUMotherboardGraphicsRAM
2xQuadCore Intel Xeon E5420 Tyan Tempest i5400XT GTX 660 Ti 16GB 8xSamsung M395T5750 FBDIMM 
Hard DriveOptical DriveOSMonitor
16 Internal, 16 external. Mainly Seagate LG GGW-H20L + GH22NP20 Windows 7 Ultimate x64 ASUS PB278Q 
KeyboardPowerCaseMouse
Corsair Vengeance K95 Enermax Galaxy 1000W EGA1000EWL Chieftec (modified) Logitech G500 
  hide details  
Reply
My System
(13 items)
 
  
CPUMotherboardGraphicsRAM
2xQuadCore Intel Xeon E5420 Tyan Tempest i5400XT GTX 660 Ti 16GB 8xSamsung M395T5750 FBDIMM 
Hard DriveOptical DriveOSMonitor
16 Internal, 16 external. Mainly Seagate LG GGW-H20L + GH22NP20 Windows 7 Ultimate x64 ASUS PB278Q 
KeyboardPowerCaseMouse
Corsair Vengeance K95 Enermax Galaxy 1000W EGA1000EWL Chieftec (modified) Logitech G500 
  hide details  
Reply
post #3507 of 7179
Does anyone know what this warning and error means? I'm thinking it's the memory that's bad.

I initially got a warning that said, "Controller ID: 0 Single-bit ECC error; warning threshold
exceeded: ECAR
= 0x510002 , ELOG = 0xcc319d10 , ( Read error from ATU on bit 65)".

Then a few hours later, the warning became a critical error, "Controller ID: 0 Single-bit ECC error; critical threshold
exceeded: ECAR
= 0x510002 , ELOG = 0xcc319d10 , ( Read error from ATU on bit 65)"
Edited by eric06303 - 11/2/09 at 5:26am
post #3508 of 7179
I'd try re-seating the memory (assuming you have a card with removable memory).
post #3509 of 7179
Hi, im new. Im searching in ebay but the perc 5 is far from 100 uss, can someboy give me a good link? (with BBU if possible) My idea is run RAID5 not spending to much

Saludos desde Argentina

EDIT: Perc 6 is a nice idea to ... mmm ... RAID5 vs RAID6, well, if the price is not so much more expensive i think about it
Edited by LuciferX - 11/3/09 at 7:04pm
Ryzen7
(9 items)
 
  
CPUMotherboardGraphicsRAM
AMD Ryzen R7 1700 Asrock X370 Professional Gaming AMD Radeon RX 470 Corsar Vengeance LPX 3000 Mhz 16GB DDR4 (2x8GB) 
Hard DriveOSMonitorPower
Samsung 840 Evo + 2 x WD + 1 Seagate Microsoft Windows 10 Pro Dell 2209WA 22" UltraSharp IPS Coolermater RealPower Pro 1000W 
Case
Phanteks Enthoo Luxe Tempered Glass 
  hide details  
Reply
Ryzen7
(9 items)
 
  
CPUMotherboardGraphicsRAM
AMD Ryzen R7 1700 Asrock X370 Professional Gaming AMD Radeon RX 470 Corsar Vengeance LPX 3000 Mhz 16GB DDR4 (2x8GB) 
Hard DriveOSMonitorPower
Samsung 840 Evo + 2 x WD + 1 Seagate Microsoft Windows 10 Pro Dell 2209WA 22" UltraSharp IPS Coolermater RealPower Pro 1000W 
Case
Phanteks Enthoo Luxe Tempered Glass 
  hide details  
Reply
post #3510 of 7179
I have a question about needing a BBU or not.

As it stands, I have a UPS unit which will supply just enough juice to enable my computer to shut down in the case of a brownout or power failure. Should I still invest in a BBU?
Edited by waLIEN - 11/5/09 at 10:04am